Research Article

Temperature Control and Crack Prevention Measures for Concrete Ship Locks Subjected to Prolonged Casting Interruptions

Table 4

Computational results of the thermal stresses of layered placement and block placement.

Operating conditionMaximum stress (MPa)
Monitoring point Elevation—1.1Monitoring point Elevation—0.8Monitoring point Elevation—0.5Monitoring point Elevation—0.2

Layered placement—no insulation3.183.112.942.65
Block placement—no insulation2.802.692.482.16
Block placement—insulation2.622.512.322.04