Table 6

The results of the MTF determination in its dosage forms using MTF-PT, MTF-PT-Al2O3NP-modified, and MTF-PT-NiONP-modified sensors with respect to the previously reported results.

MTF-PT conventional electrodeMTF-PT-Al2O3NP-
modified electrode
MTF-PT-NiONP-
modified electrode
Reference method [59]
Test sampleFound% recoveryTest sampleFound% recoveryTest sampleFound%Recovery

Statistical analysis65.9899.661010.00100.00109.9699.60
54.9799.4087.9699.7587.9499.25
4.34.2598.8365.9499.0065.9699.33
43.9899.5044.00100.0043.9398.25
32.9899.3332.9999.6732.9999.67
21.9698.0021.9899.0022.00100.00

Mean ± SD99.12 ± 0.6299.57 ± 0.4699.35 ± 0.6099.25 ± 0.72

n6666

Variance0.380.210.360.52

%SE0.250.190.240.29

%RSD0.630.460.600.74

t-test0.337 (2.228)0.922 (2.228)0.266 (2.228)

F-test1.37 (5.05)2.48 (5.05)1.44 (5.05)

The tabulated values of “t-test” and “F-test” at confidence level p = 0.05.