Research Article
Modeling and Characteristic Analysis of a Solar Parabolic Trough System: Thermal Oil as the Heat Transfer Fluid
Table 1
The system main parameters of the SEGS VI power plant [
1–
3].
| | Name | Parameters | Value | Unit |
| | Power block | Name | SEGS VI in Kramer Junction, USA | | Net capacity | 30 | MWe | | Designed oil temperature | 349 |
°C | | Solar collector area | 188000 | m2 |
| | Solar collectors | Length of single collector | 47.1 | m | | Width of single collector | 5 | m | | Area of single collector | 235 | m2 | | Focal length of the collector | 1.84 | m | | Focal ratio of the collector | 71 | — | | Absorber external diameter | 70 | mm | | Envelope external diameter | 115 | mm |
|
|