Research Article
Noninvasive Evaluation of the Biomechanical Accommodations to Bolus Volume during Human Swallowing
Table 2
Definitions of phases on the laryngeal signal waveform recorded by the bend sensor.
| Phase | Definition | Synchronized indication for hyoid motion |
| Preliminary phase of waveform | T1–T2 | Hyoid slight motion phase | Former part of the downward phase of waveform | T2–T4 | Hyoid elevation phase | Latter part of the downward phase of waveform | T4–T5 | Hyoid stabilization phase at the most anterior-superior position | Recovery phase of waveform | T5–T6 | Hyoid descent phase | Downward phase of waveform | T2–T5 | Hyoid active phase | Total phase of waveform | T1–T6 | Hyoid total motion phase |
|
|