Research Article

[Retracted] Research on Protection Performance of Surge Protective Devices against Electromagnetic Pulse

Table 7

Test results of Zener diode’s ability to suppress narrow pulse (10/100 ns).

Pulse application modeForward applicationReverse application
Number of timesInjection voltage peak
Device response residual voltage peak
Injection voltage peak
Device response residual voltage peak

113.51.6 (0.74)53.031.0 (23.0)
2565.08 (0.74)78.432.8 (28.0)
3968.76 (0.72)101.043.2 (28.0)
41209.12 (0.72)132.054.5 (29.2)
514210.2 (0.72)162.052.4 (29.2)
618621 (0.80)224.070.0 (30.0)
722122.8 (0.80)249.074.8 (30.0)

Note: The voltage in brackets is the clamping voltage value.