Research Article
Influence of Microwave Incinerated Rice Husk Ash on Hydration of Foamed Concrete
Table 5
Test results of compressive strength for MIRHA FC.
| Code | Compressive strength (N/mm2) | 3 d | 7 d | 28 d | 90 d | 180 d |
| FC-1 | 3.2 | 8.3 | 17.1 | 27.7 | 34.7 | FC-2 | 6.4 | 12.2 | 26.8 | 43.6 | 52.2 | FC-3 | 3.1 | 5.9 | 13.4 | 31.1 | 27.5 | FC-4 | 1.2 | 2.3 | 5.5 | 13.9 | 12.0 | FC-5 | 4.2 | 7.5 | 17.4 | 27.8 | 36.7 | FC-6 | 4.6 | 11.0 | 20.3 | 33.8 | 42.4 | FC-7 | 4.1 | 7.2 | 17.3 | 26.3 | 34.4 | FC-8 | 5.8 | 12.2 | 24.8 | 39.0 | 51.1 | FC-9 | 6.0 | 11.2 | 25.5 | 44.2 | 55.8 | FC-10 | 6.9 | 12.6 | 28.1 | 47.3 | 57.9 | FC-11 | 3.1 | 7.4 | 14.5 | 25.6 | 33.0 | FC-12 | 4.5 | 8.3 | 19.1 | 37.9 | 42.6 | FC-13 | 3.0 | 5.8 | 13.2 | 21.3 | 26.5 | FC-14 | 4.0 | 7.6 | 16.8 | 26.6 | 31.9 | FC-15 | 5.1 | 9.7 | 21.4 | 34.7 | 41.8 | FC-16 | 3.6 | 9.2 | 17.3 | 32.5 | 35.5 |
|
|