Research Article
Hydraulic Conductivity of Compacted Laterite Treated with Iron Ore Tailings
Table 1
Particle size analysis results of the laterite.
| Particle size (mm) | Percentage passing (%) |
| 3.35 | 100.0 | 2.00 | 99.2 | 1.18 | 96.4 | 0.60 | 90.4 | 0.30 | 79.8 | 0.015 | 68.4 | 0.075 | 48.7 | 0.050 | 42.1 | 0.035 | 38.8 | 0.025 | 36.0 | 0.018 | 34.0 | 0.013 | 31.1 | 0.010 | 29.1 | 0.007 | 27.6 | 0.005 | 24.4 | 0.004 | 19.6 | 0.003 | 16.4 | 0.002 | 9.4 |
|
|