Influence Factors on the Properties of Ultrahigh-Performance Fiber-Reinforced Concrete Cured under the Condition of Room Temperature
Table 2
Composition of the mixtures and the test results.
| | Material (kg/m3) | A1 | A2 | A3 | A4 | A5 |
| | Cement | 940 | 940 | 940 | 940 | 940 | | GGBFS | — | — | — | — | — | | FA | — | — | — | — | — | | SF | 282 | 282 | 282 | 282 | 282 | | 0-1 mm bauxite | 240 | 240 | 240 | 240 | 240 | | 1∼3 mm bauxite | 940 | 940 | 940 | 940 | 940 | | Steel fiber | 234 | 234 | 234 | 234 | 234 | | SP (L/m³) | 70.5 | 70.5 | 70.5 | 70.5 | 70.5 | | Water | 200 | 212 | 225 | 237 | 250 | | Water/binder | 0.164 | 0.174 | 0.184 | 0.194 | 0.204 | | Compressive strength (MPa) | | | | | | | 7 days | 128 | 130.5 | 115.5 | 110.6 | 120.5 | | 28 days | 149.7 | 150.5 | 145.7 | 146.5 | 141.3 | | Slump (cm) | 0 | 3.9 | 5 | 8.5 | 10.1 |
|
|