Research Article
Seismic Performance of High-Ductile Fiber-Reinforced Concrete Short Columns
Table 7
Test results and calculated results (kN).
| Specimen | Pm | Vn (ACI) | Pm/Vn (ACI) | Vn (GB) | Pm/Vn (GB) |
| RC1 | 289.5 | 206.5 | 1.40 | 258.0 | 1.12 | HDC2 | 326.0 | 196.2 | 1.66 | 301.1 | 1.08 | HDC3 | 358.2 | 212.5 | 1.68 | 313.1 | 1.14 | HDC4 | 376.9 | 228.7 | 1.64 | 325.2 | 1.16 | HDC5 | 342.4 | 194.7 | 1.76 | 295.3 | 1.16 | HDC6 | 334.3 | 182.8 | 1.82 | 283.5 | 1.18 | HDC7 | 443.9 | 212.5 | 2.08 | 350.7 | 1.26 |
|
|