Research Article
Scheme Exploration and Performance Analysis of 800-Meter Superlarge Span Structure
Table 2
Load combinations of the bearing capacity limit state (partial factor × combined factor).
| No. | Combination | Dead load | Live load | Wind load | Temperature |
| 1 | D + L | 1.35 × 1.0 | 1.4 × 0.7 | — | — | 2 | D + L | 1.2 × 1.0 | 1.4 × 1.0 | — | — | 3 | D + L + T | 1.35 × 1.0 | 1.4 × 0.7 | — | 1.4 × 0.6 | 4 | D + L + T | 1.2 × 1.0 | 1.4 × 1.0 | — | 1.4 × 0.6 | 5 | D + L + W | 1.35 × 1.0 | 1.4 × 0.7 | 1.4 × 0.6 | — | 6 | D + L + W | 1.2 × 1.0 | 1.4 × 1.0 | 1.4 × 0.6 | — | 7 | D + L + W | 1.2 × 1.0 | 1.4 × 0.7 | 1.4 × 1.0 | — | 8 | D + L + W + T | 1.35 × 1.0 | 1.4 × 0.7 | 1.4 × 0.6 | 1.4 × 0.6 | 9 | D + L + W + T | 1.2 × 1.0 | 1.4 × 1.0 | 1.4 × 0.6 | 1.4 × 0.6 | 10 | D + L + W + T | 1.2 × 1.0 | 1.4 × 0.7 | 1.4 × 1.0 | 1.4 × 0.6 | 11 | D + W | 1.0 × 1.0 | — | 1.4 × 1.0 | — | 12 | D + W + T | 1.0 × 1.0 | — | 1.4 × 1.0 | 1.4 × 0.6 |
|
|