Research Article
Experimental Research of Continuous Concrete Beams with GFRP Reinforcement
Table 5
Experimental and calculated failure loads for tested beams.
| Beam | Failure load-load-carrying capacity (kN) | | Experiment | ACI | CSA | EC2 | Exp./ACI | Exp./CSA | Exp./EC2 |
| S1-15 | 134.3 | 90.1 | 88.8 | 90.1 | 1.49 | 1.51 | 1.49 | G1-0 | 115.6 | 115.4 | 126.3 | 141.3 | 1.00 | 0.92 | 0.82 | G1-15 | 115.2 | 111.8 | 123.0 | 137.0 | 1.03 | 0.94 | 0.84 | G1-25 | 119.6 | 117.4 | 128.6 | 143.8 | 1.02 | 0.93 | 0.83 | G2-0 | 125.2 | 113.6 | 128.0 | 145.2 | 1.10 | 0.98 | 0.86 | G2-15 | 124.9 | 117.2 | 131.7 | 149.8 | 1.07 | 0.95 | 0.83 | G2-25 | 137.8 | 110.8 | 125.2 | 141.7 | 1.24 | 1.10 | 0.97 |
|
|