Research Article

Experimental and FEM Investigation of Cob Walls under Compression

Table 4

Comparison between mechanical parameters obtained for Wall A tested at 0.025 MPa/min and mean values obtained from other specimens (0.077 MPa/min).

σ1 (MPa)σ2 (MPa)fc (MPa)ɛfc (%)E01 (MPa)E1/3 (MPa)ν01 (−)ν1/3 (−)ωi (%)ωe (%)

Mean BCD0.150.701.127.6316.9015.370.120.074.084.21
Wall A-10.060.681.354.8323.7321.470.090.064.113.43
Wall A-20.741.6634.6830.214.113.43