Research Article

Seismic Performance of a Corroded Reinforce Concrete Frame Structure Using Pushover Method

Table 9

Seismic bearing capacity of the corroded frame under rare earthquake action.

Corrosion rate (%)Maximum base shear (kN)
Under the uniform load patternUnder the 1st modal load pattern

0.0628.5518.5
5.0581.9479.6
10.0508.1417.7
18.0359.2290.3