Research Article

Theoretical and Experimental Study on the Antisliding Performance of Casting Steel Cable Clamps

Table 4

Ultimate antisliding force and comprehensive friction coefficient.

SpecimenCable tension force (kN)Sum of effective bolt clamping force (kN)Ultimate antisliding force (kN)Comprehensive friction coefficient

Φ100-14240404.1282.90.35
Φ100-2410.4274.30.33

Φ116-14277978.6591.80.30
Φ116-2934.4865.30.46

Φ127-16756980.7723.50.37
Φ127-2969.0653.30.34

Φ140-16511883.8717.10.41
Φ140-2892.2703.90.39