Research Article
Theoretical and Experimental Study on the Antisliding Performance of Casting Steel Cable Clamps
Table 5
Average bolt clamping force at different stages.
| Specimen | Average bolt clamping force (kN) | Reduction percentage of bolt clamping force | Initial stage | Creep stable stage | Cable tension stage | Initial stage | Creep stable stage | Cable tension stage |
| Φ100-1 | 234.4 | 156.6 | 101.0 | — | 33.2% | 56.9% | Φ100-2 | 237.3 | 158.4 | 102.6 | — | 33.3% | 56.8% | Φ116-1 | 230.8 | 166.8 | 122.3 | — | 27.7% | 47.0% | Φ116-2 | 229.7 | 161.1 | 116.8 | — | 29.8% | 49.1% | Φ127-1 | 242.4 | 173.0 | 122.6 | — | 28.6% | 49.4% | Φ127-2 | 230.7 | 172.2 | 121.1 | — | 25.4% | 47.5% | Φ140-1 | 228.0 | 167.7 | 110.5 | — | 26.4% | 51.5% | Φ140-2 | 226.7 | 168.0 | 111.5 | — | 25.9% | 50.8% |
|
|