Research Article

Experimental Research on the Transverse Effective Bending Rigidity of Shield Tunnels

Table 4

Values of η calculated based on the formulas proposed in this paper.

TypesC/D
123456

Straight-jointed0.530.590.640.670.700.72
Stagger-jointed0.680.730.760.780.800.82