Research Article
Evaluation of the American Approach for Detecting Plan Irregularity
Figure 8
Ratios between maximum δmax and average displacement δavg, at varying CM position. Comparison between linear dynamic analysis (continuous line) and linear static analysis (dotted line). The position of CM is given in % of the building longitudinal dimension (L = 48.85 m); for e = 0%, CM is in the actual position.