Research Article

A Comparative Test Study on the Seismic Damage Sustained by Frame-Core Tube Structures

Table 4

Value of in frame column.

ComponentFloorStirrupFlexural reinforcement
Corner columnSide column

Frame column1∼5F11.51.5
6∼10F11.261.26
11∼15F11.41.4
16∼25F111