Research Article
Analytical Investigation of the Flexural Capacity of Precast Concrete Frames with Hybrid Joints
Table 8
Comparison of analytical values to test data at the yield and maximum load state (units: kN and kN·m) [
19].
| Specimens | Data | Yield limit state | Maximum load state | Load (moment) | Strain | Load (moment) | Strain |
| Specimen #1 | Analytical | 125.3 kN (188.0 kN·m) | 0.0022700 | 130.3 kN (195.5 kN·m) | 0.0202700 | Experimental | 130.7 kN (196.1 kN·m) | 0.0038640 | 136.8 kN (205.2 kN·m) | 0.0011754 | Error | 4.0% | — | 5.0% | — |
| Specimen #2 | Analytical | 162.9 kN (244.3 kN·m) | 0.0022700 | 176.3 kN (264.5 kN·m) | 0.0157100 | Experimental | 169.6 kN (254.4 kN·m) | 0.0027120 | 195.9 kN (293.9 kN·m) | 0.0042350 | Error | 4.1% | — | 11.1% | — |
| Specimen #3 | Analytical | 287.2 kN (430.8 kN·m) | 0.0022700 | 348.0 kN (522.0 kN·m) | 0.0060000 | Experimental | 319.8 kN (479.7 kN·m) | 0.0031820 | 354.3 kN (531.5 kN·m) | 0.0038640 | Error | 11.4% | — | 1.8% | — |
|
|