Research Article
Comparative Study on Mechanical Properties of a Tube-Crushing Dissipator and a Symmetric Tube-Crushing Dissipator
Table 3
Main mechanical parameters of the tube-crushing dissipators at static tests.
| Tube thickness (mm) | No. | Activation force threshold (kN) | Absorbed energy (kJ) | Mean force at the crushing section (kN) |
| 0.4 | Sample 1 | 10.99 | 1.18 | 8.24 | Sample 2 | 10.81 | 1.24 | 8.73 | Sample 3 | 10.66 | 1.28 | 8.72 | Average | 10.82 | 1.23 | 8.56 |
| 0.5 | Sample 1 | 15.94 | 2.00 | 12.64 | Sample 2 | 14.83 | 1.74 | 11.62 | Sample 3 | 15.59 | 1.75 | 12.13 | Average | 15.45 | 1.83 | 12.13 |
| 0.55 | Sample 1 | 17.60 | 1.85 | 12.69 | Sample 2 | 18.21 | 1.90 | 14.04 | Sample 3 | 17.49 | 2.09 | 14.33 | Average | 17.77 | 1.95 | 13.69 |
|
|