Research Article
Comparative Study on Mechanical Properties of a Tube-Crushing Dissipator and a Symmetric Tube-Crushing Dissipator
Table 4
Main mechanical parameters of the symmetric tube-crushing dissipators at static tests.
| Tube thickness (mm) | No. | Activation force threshold (kN) | Absorbed energy (kJ) | Mean force at the crushing section (kN) |
| 0.4 | Sample 1 | 22.15 | 3.42 | 21.62 | Sample 2 | 24.46 | 3.14 | 20.08 | Sample 3 | 22.61 | 3.05 | 20.01 | Average | 23.07 | 3.20 | 20.57 |
| 0.5 | Sample 1 | 25.55 | 4.26 | 26.84 | Sample 2 | 32.45 | 4.82 | 29.81 | Sample 3 | 29.05 | 5.09 | 31.75 | Average | 29.02 | 4.72 | 29.46 |
| 0.55 | Sample 1 | 36.32 | 5.17 | 30.21 | Sample 2 | 33.35 | 4.85 | 31.11 | Sample 3 | 30.35 | 5.02 | 32.03 | Average | 33.34 | 5.01 | 31.12 |
|
|