Research Article
Experimental Study on Hysteretic Behavior of Double-Plate Reinforced Overlapped K-Joints
Table 2
Test result of steel tubular material properties.
| Specification | fy (MPa) | fu (MPa) | E (GPa) | εy = fy/E | fu/fy | δ (%) |
| 200 × 200 × 8 | 391.1 | 533.0 | 226.2 | 0.0017 | 1.36 | 35.3 | 95 × 5 | 377.6 | 515.6 | 214.6 | 0.0017 | 1.37 | 25.9 | 159 × 6 | 386.5 | 531.5 | 222.4 | 0.0017 | 1.38 | 34.2 | 89 × 5 | 373.1 | 510.1 | 210.2 | 0.0018 | 1.37 | 26.6 |
|
|