Research Article

Analytical Solution for Lateral-Torsional Buckling of Concrete-Filled Tubular Flange Girders with Torsional Bracing

Table 10

The sizes of the sections.

ParameterH (mm)bf (mm)tf (mm)t (mm) (mm) (mm)Flange steel ratio (%)L (mm)

Section 1600160601.848048.1216000
Section 2600160602.148049.4416000
Section 3600160602.4480410.7616000
Section 4600160602.7480412.0716000
Section 5600160603.0480413.3816000
Section 6600160603.3480414.6716000
Section 7600160603.6480415.9616000
Section 8600160603.9480417.2416000
Section 9600160604.2480418.51516000
Section 10600160604.5480419.7816000