Research Article

Optimization of Cable Force Adjustment in Cable-Stayed Bridge considering the Number of Stay Cable Adjustment

Table 1

Characteristics of cross sections.

Control sectionA (m2)Iy (m4)Iz (m4)E (MPa)L (MPa)

Main girder2421.73571.43550017.8
Main pylon (top)15.459.727.33350016.2
Main pylon (bottom)38.1254.9165.93350016.2
Pile foundation3.81.151.153000010.05
Steel wirePES7-1630.006
PES7-1990.008
PES7-2230.00900205000708
PES7-2830.011
PES7-3130.012

Note: A = cross-sectional area; Ix = moment of inertia for the x-axis; Iy = moment of inertia for the y-axis; E = elastic modulus; L = limit value of the stress.