Research Article

Experiment Study on Dynamic Effects of Tower-Line Systems Induced by Ice Shedding

Table 3

Comparison of test frequency and design frequency.

Research objectVibration modeTest frequency (Hz)Design frequency (Hz)Error (%)

Tension towerFirst order23.0522.154.07
Second order23.4922.464.56

Tangent towerFirst order7.6257.8132.47
Second order7.6787.8612.38

First-span conductorFirst order0.8040.8303.23
Second order1.0581.0741.51

Second-span conductorFirst order1.1311.1723.62
Second order1.6311.7094.78