Research Article
Experiment Study on Dynamic Effects of Tower-Line Systems Induced by Ice Shedding
Table 3
Comparison of test frequency and design frequency.
| Research object | Vibration mode | Test frequency (Hz) | Design frequency (Hz) | Error (%) |
| Tension tower | First order | 23.05 | 22.15 | 4.07 | Second order | 23.49 | 22.46 | 4.56 |
| Tangent tower | First order | 7.625 | 7.813 | 2.47 | Second order | 7.678 | 7.861 | 2.38 |
| First-span conductor | First order | 0.804 | 0.830 | 3.23 | Second order | 1.058 | 1.074 | 1.51 |
| Second-span conductor | First order | 1.131 | 1.172 | 3.62 | Second order | 1.631 | 1.709 | 4.78 |
|
|