Research Article
FE Modeling for Bolted Wood Connection Using a Porous Constitutive Model
Table 1
The information of wood cylinder specimens for confined compression tests.
| | 
 |  | Specimen no. | Mass (g) | Initial length (mm) | Initial void ratio |  | 
 |  | S1 | 4.317 | 33.10 | 3.03 |  | S2 | 3.863 | 29.92 | 2.98 |  | S3 | 4.638 | 32.94 | 2.74 |  | S4 | 5.272 | 38.82 | 2.87 |  | S5 | 5.768 | 41.90 | 2.82 |  | S6 | 5.459 | 43.44 | 3.19 |  | S7 | 4.188 | 31.74 | 2.99 |  | 
 | 
 |