Research Article

Calculative Width of Pile Foundation on Slope Based on Particle Image Velocimetry (PIV)

Table 10

m-value based on calculative width recommended by code.

Stake number1#3#6#8#

Slope (°)0153045
Pile length (m)10.510.210.510.5
Embedment depth (m)9.859.679.829.92
Density (g/cm3)2.52.52.52.5
m-value (MN/m4)110.0142.6730.3521.47