Research Article

Analysis of Dynamic Response and Fatigue Life of Masonry Pagoda under the Influence of Train Vibration

Table 4

Comparison of test results and calculated results of autopower frequency of Liangxiang Pagoda.

Test results

DirectionThe 1st orderThe 2nd orderThe 3rd order
East-west direction13.256
South-north direction13.255.875

Calculated results
DirectionOperating modeCalculated valueDeviationCalculated valueDeviationCalculated valueDeviation

East-west direction10.95−0.053.630.387.401.40
20.89−0.113.400.156.920.92
30.90−0.103.460.217.151.15
40.92−0.083.290.046.660.66
50.93−0.073.260.016.550.55

South-north direction10.95−0.053.610.367.371.495
20.89−0.113.380.136.891.015
30.90−0.103.440.197.111.235
40.93−0.073.270.026.620.745
50.93−0.073.24−0.016.520.645