Research Article

Study on FSI Analysis Method of a Large Hydropower House and Its Vortex-Induced Vibration Regularities

Table 1

Computational parameters.

Design parameters of the turbineMaterial parameters of the structure
ConcreteSteel

Rated head H (m)100Density ρc (kg/m3)2500Density ρs (kg/m3)7800
Flow rate Q (m3/s)890Elastic modulus Ec (GPa)21Elastic modulus Es (GPa)210
Rated rotation speed n (rpm)75Poisson ratio μc0.167Poisson ratio μs0.3