Research Article

Restoring Force Model of an Energy-Dissipation Joint in Hybrid Frames: Simplified Skeleton Curve and Hysteretic Rules

Table 11

Comparison of the ductility from the experimental and the simplified skeleton curves.

SpecimenJ-6-1J-8-1J-8-2J-8-3

Ductility of the test2.953.203.013.04
Ductility of the simplified skeleton curve2.763.023.023.02
Error (%)6.445.630.330.66