Comparison of FEM and experimental test frequency.
| | 
 |  | Mode shape | Field test frequency (Hz) | FEM I (fixed) | FEM II (simple) |  | Frequency (Hz) | Relative error (%) | Frequency (Hz) | Relative error (%) |  | 
 |  | Order 1 | 5.96 | 6.18 | 3.56 | 4.36 | −26.85 |  | Order 2 | 8.62 | 8.89 | 3.04 | 7.06 | −18.10 |  | Order 3 |  | 11.68 |  | 7.86 |  |  | Order 4 | 12.22 | 12.26 | 0.08 | 9.43 | −22.83 |  | Order 5 |  | 14.45 |  | 9.86 |  |  | Order 6 | 15.15 | 15.86 | 4.48 | 10.13 | −33.14 |  | 
 | 
 |