Advances in Civil Engineering / 2020 / Article / Tab 1 / Research Article
Mining Failure Response Characteristics of Stope Floor: A Case of Renlou Coal Mine Table 1 Installation parameters of fixed-point fiber grating position.
Section number Grating installation sequence Hole length (m) Vertical depth from floor (m) Remarks Section 3 1 40.50 31.01 Please install Section 3 of the optical fiber first, and then install Sections 2 and 1 in sequence; next, install the first fixed-point grating 1.5 m from the bottom of the hole 2 38.50 29.48 3 36.50 27.95 4 34.50 26.42 5 32.50 24.89 6 30.50 23.36 7 28.50 21.82 8 26.50 20.29 Section 2 9 24.50 18.76 10 22.50 17.23 11 20.50 15.70 12 18.50 14.17 13 16.50 12.64 14 14.50 11.10 15 12.50 9.57 16 10.50 8.04 Section 1 17 8.50 6.51 The fixed-point grating closest to the orifice is 2.5 m away from it 18 6.50 4.98 19 4.50 3.45 20 2.50 1.91