Research Article
In Situ X-Ray Computed Tomography (CT) Investigation on Localized Deformation and Crack Damage Evolution in a Bimrock by Tracking Rock Blocks
Table 1
The detailed performance index of the 450 kV industrial x-ray CT system.
| | Performance parameter of the CT device | Index | Unit |
| | Effective scanning diameter | Φ800 | mm | | Effective scanning height | Φ1000 | mm | | Maximum scanned weight | 200 | kg | | Penetration thickness for Fe | 50 | mm | | Spatial resolution | 0.07 × 0.07 × 0.07 | mm3 | | Perspective of relative sensitivity | 1 | % | | Density resolution | 0.1 | % | | Minimum scanning thickness | 0.03 | mm | | Fastest scanning time | 1 | min | | Image reconstruction time | 30 | s | | Resolution capacity for crack | 0.05 × 15 | mm2 | | Stomata resolution | Φ0.3 | mm | | Resolution for inclusion | 0.1 | mm | | Localization accuracy of the workbench | ±0.02 | mm | | Accuracy of the turntable | ±5° | /s |
|
|