Journals
Publish with us
Publishing partnerships
About us
Blog
Advances in Civil Engineering
Journal overview
For authors
For reviewers
For editors
Table of Contents
Special Issues
Advances in Civil Engineering
/
2020
/
Article
/
Tab 9
/
Research Article
Model Experimental Study of Carbon Fiber Heating Wire for Deicing and Snow Melting on a Bridge Deck
Table 9
Temperature change rate of the first layer’s measurement points Nos. 25, 26, and 27 of the ice melting experiment.
Environmental conditions (°C)
Initial average temperature (°C)
Average temperature when rising for 250 min (°C)
Temperature change rate (°C/h)
−2
−0.12
4.83
1.189
−4
−0.63
3.08
0.891
−8
−0.67
1.58
0.541