Comparison between predicted capacities and test results for intact CFST column specimens.
| Section types | No. | Specimen number | Nue (kN) | AIJ [17] | AISC3610-10 [18] | BS5400 [19] | DBJ13-51-2010 [20] | Eurocode 4 [21] | Nuc (kN) | Nuc (Nue) | Nuc (kN) | Nuc (Nue) | Nuc (kN) | Nuc (Nue) | Nuc (kN) | Nuc (Nue) | Nuc (kN) | Nuc (Nue) |
| Square | 1 | sc1-1 | 3074 | 2572 | 0.837 | 2611 | 0.849 | 1916 | 0.623 | 2835 | 0.922 | 2914 | 0.948 | 2 | sc1-2 | 3125 | 2572 | 0.823 | 2611 | 0.836 | 1916 | 0.613 | 2835 | 0.907 | 2914 | 0.932 |
| Circular | 3 | cc1-1 | 2721 | 2202 | 0.809 | 2209 | 0.812 | 1966 | 0.723 | 2300 | 0.845 | 2573 | 0.946 | 4 | cc1-2 | 2705 | 2202 | 0.814 | 2209 | 0.817 | 1966 | 0.727 | 2300 | 0.850 | 2573 | 0.951 |
|
|