Research Article
Mathematical Model for Analysis of Uniaxial and Biaxial Reinforced Concrete Columns
Table 4
Biaxial column input data.
| Column identifier | Pu (kN) | Mux (kN·m) | Muy (kN·m) | (mm2) | (mm2) | (MPa) | (MPa) | | (mm) | (mm) | (mm) |
| CB-1 (300 × 600) | 300 | 100 | 80 | 1232 | 1232 | 30 | 400 | 0.65 | 80 | 267 | 333 | CB-2 (200 × 400) | 200 | 40 | 20 | 628.4 | 628.4 | 20 | 300 | 0.7 | 40 | 100 | 200 | CB-3 (300 × 300) | 2500 | 250 | 120 | 1225 | 1225 | 30 | 400 | 0.65 | 70 | 48 | 100 | CB-4 (375 × 500) | 1700 | 200 | 100 | 2100 | 2100 | 30 | 415 | 0.65 | 60 | 59 | 118 | CB-5 (400 × 500) | 800 | 200 | 50 | 1413.8 | 1413.8 | 30 | 415 | 0.65 | 60 | 62.5 | 250 | CB-6 (350 × 700) | 400 | 60 | 40 | 1638 | 1638 | 20 | 300 | 0.65 | 45 | 100 | 150 | CB-7 (400 × 1200) | 1500 | 300 | 300 | 3080 | 3080 | 20 | 300 | 0.65 | 60 | 200 | 200 |
|
|