Research Article

Mathematical Model for Analysis of Uniaxial and Biaxial Reinforced Concrete Columns

Table 4

Biaxial column input data.

Column identifierPu (kN)Mux (kN·m)Muy (kN·m) (mm2) (mm2) (MPa) (MPa) (mm) (mm) (mm)

CB-1 (300 × 600)3001008012321232304000.6580267333
CB-2 (200 × 400)2004020628.4628.4203000.740100200
CB-3 (300 × 300)250025012012251225304000.657048100
CB-4 (375 × 500)170020010021002100304150.656059118
CB-5 (400 × 500)800200501413.81413.8304150.656062.5250
CB-6 (350 × 700)400604016381638203000.6545100150
CB-7 (400 × 1200)150030030030803080203000.6560200200