Research Article
Mathematical Model for Analysis of Uniaxial and Biaxial Reinforced Concrete Columns
Table 6
Experimental testing data [
22].
| Experimental investigator | Column identifier with size (in x in) b (mm x mm) | As (In2) (mm2) | (Ksi) (MPa) | (Ksi) (MPa) | (In) (mm) | (in) (mm) | (in) (mm) |
| Bresler (uniaxial column) | B-1 (6 × 8) (152 × 203) | 1.24 (800) | 3.7 (25.6) | 53.5 (369) | 1.75 (44.5) | 6 (152.4) | 0 | Bresler (uniaxial column) | B-2 (6 × 8) (152 × 203) | 1.24 (800) | 3.9 (27) | 53.5 (369) | 1.75 (44.5) | 3 (76.2) | 0 | Anderson and Lee (biaxial column) | SC-4 (4 × 4) (102 × 102) | 0.8 (516) | 5.435 (37.5) | 45.6 (314.6) | 0.75 (19) | 2.82 (71.63) | 2.82 (71.63) |
|
|