Research Article

Effect of Hybrid Steel-Basalt Fiber on Behaviors of Manufactured Sand RPC and Fiber Content Optimization Using Center Composite Design

Table 12

ANOVA results for response surface quadratic model parameters.

ResponsesSourceSOSDFMSF-value valueR

28-day compressive strength (R1)Model626.525125.30107.56<0.0001Sign.
A520.471520.47446.78<0.0001Sign.
B28.85128.8524.760.0016Sign.
AB30.80130.8026.440.0013Sign.
A225.41125.4121.810.0023Sign.
B227.03127.0323.200.0019Sign.
Residual8.1571.16
Lack of fit5.8431.953.360.1360Not sign.
Pure error2.3240.5789

28-day flexural strength (R2)Model90.44518.09245.66<0.0001Sign.
A74.60174.601013.12<0.0001Sign.
B1.5811.5821.500.0024Sign.
AB2.0612.0627.970.0011Sign.
A211.33111.33153.83<0.0001Sign.
B21.8711.8725.400.0015Sign.
Residual0.515470.0736
Lack of fit0.122930.04100.41760.7505Not sign.
Pure error0.392540.0981

28-day flexural-compressive ratio (R3)Model21.5954.32193.8<0.0001Sign.
A16.37116.37732.68<0.0001Sign.
B0.164910.16497.380.0299Sign.
AB0.270410.270412.100.0103Sign.
A24.7714.77213.46<0.0001Sign.
B20.173710.17377.770.0270Sign.
Residual0.156470.0223
Lack of fit0.060730.02020.84520.5365Not sign.
Pure error0.095740.0239

SOS: sum of squares; DF: degree of freedom; MS: mean square; R: remark; Sign.: significant.