Research Article

Shear Strength of Flat Joint considering Influencing Area of Bolts

Table 4

Comparison between calculated and measured values of shear strength of the two models.

CategoryNormal stress (MPa)τtest (MPa)RectangleCircle
τcal (MPa)E (%)τcal (MPa)E (%)

Joint-1-45°0.451.165.89407.80.9617.2
0.891.446.43346.51.504.2
1.331.986.97252.02.053.5
1.782.697.52179.62.603.3
2.222.328.07247.83.1435.3
Joint-2-45°0.451.206.43435.81.172.5
0.891.587.06346.81.7913.3
1.332.247.68242.92.428.0
1.783.118.33167.83.061.6
2.224.428.95102.53.6916.5
Joint-3-45°0.451.916.73252.41.4026.7
0.892.837.40161.52.0826.5
1.332.728.08197.12.751.1
1.783.308.77165.83.454.5
2.223.749.45152.74.1210.2
Joint-1-90°0.450.653.24398.50.8429.2
0.890.933.71298.91.3140.9
1.331.494.18180.51.7819.5
1.782.514.6786.12.2610.0
2.223.075.1467.42.7311.1
Joint-2-90°0.450.993.71274.70.981.0
0.891.394.26206.51.529.4
1.332.794.8072.02.0626.2
1.782.795.3591.82.616.5
2.223.125.8988.83.161.3
Joint-3-90°0.451.134.82326.51.2510.6
0.891.965.52181.61.950.5
1.332.836.23120.12.666.0
1.783.416.95103.83.380.9
2.222.987.65156.74.0836.9
Eave (%)210.512.8