Abstract

Precast concrete segmental (PCS) box-girders are widely used in bridge construction, while studies on flexural behaviors of PSC box-girders with dry joints are insufficient. Six large-scale PCS box-girders with dry joints were tested to failure under two-point loading in this study. Strain increments, tendon forces, deflections at mid-span, and cracks were recorded during the tests. Multiple factors were investigated with regards to their influence on flexural performance of girders. It is found that most specimens failed due to the excessive force in tendons, while the specimen with external tendons failed due to concrete compressive crushing. Larger shear span ratio resulted in greater increase in tendon force and concrete strain during loading and, accordingly, the lowest ultimate flexural capacity. Lower concrete strength resulted in larger increase in concrete strain and tendon force during loading and relatively smaller deflection at failure. For the specimen with four segments, a significant increase in tendon force and smaller deflections at failure was observed as compared with specimen 1, though the failure load was similar. Numerical simulation is further conducted, where it is found that the area of prestressed tendon and the number of joints have a significant influence on ultimate flexural bearing capacity and deflection; besides, deflection control standard of PCS girders should be stricter than that of the integral cast girder. The corbel joints, in general, show better ultimate performance than the castle-shaped joints.

1. Introduction

Precast concrete segmental (PCS) girders have been widely applied in mid-/long-span bridges due to their rapid assembly, excellent quality control, low life-cycle cost, and mitigated environmental disturbance. In the past decades, extensive studies were conducted on PCS girder bridges concerning the shear strength of epoxy and dry joints with various geometries [15]. It was observed that the average shear strength in multiple-keyed dry joints is less than that in single-keyed dry joints in view of imperfections in occlusion of keys [1] and the failure of the epoxied joints was brittle [2]. Alcalde pointed out that as the number of shear keys increases, shear stress across the joint decreases [3]. Numerical evaluation of the shear behavior of a Ferro Casting Ductile (FCD) metal shear key [4] indicated that a combination of high-quality concrete and higher prestressing force would be safer when a FCD shear key is applied in segmental dry joints. Additionally, it is observed that shear capacity of the joints increased by approximately 40% as the confining stress increased by 50% [5].

Besides, behavior of PCS girders with internal, external, or hybrid tendons [610] and performance of girder under different loading (i.e., pure bending and combined shear and bending) have been investigated, although currently, such studies are still limited. Yuan investigated the influence of two different loading types and indicated that three-point bending load could reduce the vertical deflection at the onset point of nonlinearity [7]. Jiang studied flexural behavior of precast segmental beams with hybrid tendons and revealed that flexural strength of fully segmental beams with hybrid tendons is 30% less than that of the monolithic beam [8]. The failure mode of dry joints is different from that of epoxied joints, and stirrups contribute little to the bearing capacity of the segmental interface under combined shear and bending; thus, the stirrups are not included as factors in this experiment [9].

More recently, steel fibers were used in PCS girders to increase shear strength and ductility [1115]. Turmo [16] investigated unbonded precast segmental girders with steel fiber-reinforced concrete and found that conventional shear reinforcement is ineffective in the shear capacity test. Load bearing capacity of ultra-high-performance fiber-reinforced concrete structures with dry joints was investigated experimentally and theoretically [17]. Tests on precast segmental beams with an unboned carbon fiber-reinforced polymer (CFRP) tendon showed that stresses in the tendons in the ultimate loading condition were low, ranging from only about 66% to 72% of the nominal breaking tensile strength [18]. A parametric study was performed to investigate the influence of panel thickness, concrete strength, and bolt pattern on the performance of the fiber-reinforced beams [19].

However, more investigations are still needed to reveal the flexural behavior of PCS box-girders with dry joints, such as the influence of concrete strength, the number of shear keys, shear span ratio, odevity of the segment number, and hybrid use of tendons. Besides, comparison between precast segmental box-girders and monolithic ones requires further investigation, so as to develop a specific deflection control criterion for the precast girders and to improve bridge design. In this study, six large-scale PCS box-girders with dry joints were tested to failure under two-point loading. Strain increments, tendon forces, deflections at mid-span, and cracks were monitored and recorded during the tests. Multiple factors, such as concrete strength, odevity of the segment number and the number of shear keys, shear span ratio, and layout of tendons, were investigated with regards to their influence on the flexural performance of girders. Numerical models are developed and validated based on the test results, and the influences of other parameters not considered in the tests are investigated.

2. Description of Stepwise Loading Tests

2.1. Test Specimen

In this study, six PCS box-girders were manufactured with the length of 4 m, being 1/8 scaled of simply-supported girders used in the Jinghu high-speed railway [20], and the relatively large-scaled specimens guarantee the authentic representing of real structures. Characteristics of specimens are displayed in Table 1. Sustained loading was applied for more than one year prior to the tests [21]. The specimens except specimen 2 are made of C50 concrete with the mean compressive strength of 55.2 MPa, while specimen 2 used C40 concrete with the mean cubic compressive strength of 44.3 MPa. Two bonded prestress strands were placed symmetrically in specimens 1 to 5, as shown in Figure 1, while specimen 6 adopted a hybrid tendon layout with two internally bonded and two externally unbonded ones, as shown in Figure 2. The nominal strength of all the strands is 1860 MPa, and the net cross-sectional area of strands is 139 mm2. An HRB400-grade hot-rolled ribbed bar with the diameter of 8 mm and the nominal yield strength 400 MPa was used both for longitudinal reinforcements and transverse stirrups, and the stirrup spacing was 100 mm in all segments.

As shown in Figure 3, all the girders are symmetrically loaded at two points with a contact area of 300  mm × 300 mm. The distance from the center line of the steel plate to the support is 1.075 m except for specimen 4 (with the distance of 1.205 m), and accordingly, the shear span ratio of specimen 4 is 3.09 while that of the other girders is 2.76. Girder segments in the pure bending zone are the focus of this study. EM sensors and vibrating wire strain gauges (VWSGs) were installed at the mid-span to measure the change in tendon forces and tensile strains, respectively. In addition, concrete strain gauges were pasted at the mid-span with the distances of 60 mm, 180 mm, and 325 mm to the lower girder surface, respectively. Displacement gauges were placed at the mid-span and two girder ends, as shown in Figure 4.

During the tests, the girders were subjected to increasing static load. Before the loading reached 120 kN (i.e., the predicted yielding load), the load increment was 10 kN; thereafter, 5 kN was adopted to better describe the nonlinearity in this stage. During the loading, joints between segments were gradually opening with cracks accumulating at the root of shear keys. Figure 5 shows specimens 1 and 4 under the final step loading, where significant joint opening could be observed. Besides, joints in the pure bending region showed larger opening than the others. When the loading approached the ultimate state, the sound of concrete crushing and spalling can be heard.

2.2. Results and Discussion

For specimens 1 to 5, they were regarded failed when tendon forces approached the ultimate value (i.e., 260 kN), followed by the rapid increase in girder deflections. Note that the rate of deflection during the test ranged from 0.188 mm/min (at the beginning) to 2.738 mm/min (at the end of test). Table 2 shows the original and final tendon forces during the tests. To avoid the sudden rupture of the tendons, the loading was not actually reached 260 kN, but stopped at 238.02 kN to 258.79 kN for specimens 1 to 5. Figure 6 further shows the increase in tendon forces during the loading, where the data acquisition frequency was 0.1 Hz. It is found that specimen 4 with larger shear span ratio had the fastest increase in tendon forces, while the change in specimen 6 is mild since there were another two external tendons in this specimen. Other specimens (i.e., specimens 2, 3, and 5) showed slightly faster increase in tendon forces than specimen 1. For specimen 6, the failure occurred when the compressive crushing appeared at the top flange of the girders, while due to the sufficient internal and external tendons, the final tendon forces were only about half of those in other specimens. Besides, there was an increase of 55.82 kN in tendon force of internal tendon (bonded), while at the anchor, the increase was only 0.083 kN. For the external tendon (unbonded) in specimen 6, the increase was 58.53 kN, which is basically identical to that of internal tendon at mid-span.

According to the load-deflection curves in Figure 7, specimen 4 showed the lowest flexural capacity among the six girders, showing the significant influence of the shear span ratio. The ultimate deflection of specimens 5 is much smaller than that of specimens 1 although the ultimate bearing capacities are close to each other. This is because specimen 5 has an even number of segments (i.e., four) and there was a segment joint at the girder mid-span, resulting in the reduction in local bending stiffness and larger tendon forces. Specimen 2 also showed comparatively smaller deflection at failure, due to its lower concrete strength that resulted in larger tendon force increments. In general, the flexural capacities of specimens 1, 2, 3, and 5 are close to each other. The ultimate bearing capacity of specimen 6 is significantly higher than that of the others as there were more tendons; accordingly, the deflection at failure was comparatively small since the stiffness of specimen 6 is very large.

Figure 8 demonstrates the change in concrete strains obtained from the strain gauges embedded near the bottom of the girders at the mid-span. In general, the strain increments of specimens 2 and 4 are much larger than those of the others, as shown in Figure 8(a), indicating that the concrete grade and span ratio significantly affect the strain increments. Specimen 4 showed a sudden drop in strain increments during the final load step, which was probably due to the concrete tensile fracture near the mid-span of the girder. The strain increments in specimen 3 were close to those in specimen 1 (both were comparatively small), showing that the number of shear keys has an insignificant influence on strain increments, and specimens 1 and 3 have relatively smaller strain increments. Specimen 5 has slightly larger strain increments than specimens 1 and 3, which is probably due to the fact that this specimen has four segments and the joint coincides with the mid-span section, which weakened the local stiffness. For specimen 6 with hybrid tendons, the external tendons increased the bearing capacity significantly, as shown in Figure 8(b); accordingly, the strain increments kept increasing to 400 με in the final step. Such a large increment is due to that larger initial compressive stress existed in specimen 6 since there were another two external tendons.

Figure 9 shows the strain distribution along girder heights of specimen 1, where values under different load levels (i.e., 30, 60, 90, and 120 kN) were recorded. Two cross sections were selected for measurements, i.e., the mid-span cross section (section 1) and the cross section near shear keys (section 2, with a distance of 400 mm to mid-span), as shown in Figure 1. As the loads increased, the height of the compressive zone decreased and the neutral axis shifted upward, while the assumption of the plane section was kept prior to the load of 60 kN. Thereafter, significant nonlinear strain distributions were observed, which is due to the gradual opening of joints. It is also found that the compressive strains increased faster in Figure 9(b) than those in Figure 9(a), which is due to the existence of shear joints that weakened the cross section and high normal stiffness between shear keys.

The initial cracking loads of specimens 1 to 6 were 40 kN, 36 kN, 30 kN, 20 kN, 30 kN, and 60 kN, respectively. It is found that specimen 4 with larger shear span ratio and specimen 6 with hybrid tendons had the smallest and largest cracking loads, respectively. Lower concrete strength, even number of segments, and more shear keys resulted in lower initial cracking loads.

Figures 10 and 11 show the crack distributions on the front and back profiles of specimens 1 and 5, where cracks in specimen 1 were mainly at the joints in pure bending, while the cracking in the combined bending and shear zone were much fewer. However, for specimen 5, cracks are found at all three joints. Figure 12 further compares the cracking of top flanges of the two specimens, where concrete crushing in specimen 1 was observed at the joint near mid-span, while there were more cracks in specimen 5 but no crushing.

3. Numerical Simulation and Parametric Analysis

3.1. Numerical Modeling

The tested girders were modeled by using the finite element software DIANA, and the eight-node composite degenerated curved shell element CQ40S was used to simulate concrete element, as shown in Figure 13, which is capable of simulating the mechanical behavior of thin-walled post-tensioned concrete structures and facilitates modeling of embedded distributed reinforcement and bonded prestressed tendons [22]. The nonprestressed reinforcements in two perpendicular directions are automatically embedded in shell elements and modeled via reinforcement grid elements. The thickness of each layer of grid is determined according to the spacing and diameter of the steel reinforcements, and the location point defines the position of the grid in the thickness direction of the shell element. In CQ40S, the integration scheme over the element area is a reduced 2 × 2 Gauss integration, while in the thickness direction, 3-point Simpson integration is applied [22].

Tendons shown in Figure 13(e) were modeled through the reinforcement bar element in DIANA, which are automatically generated and defined with a few location points and shape functions. DIANA searches the shell elements for the intersections of the tendons with the shell element boundaries. These intersections serve as location points, which define the relationship of the tendons to their surrounding shell elements. The tendons are divided into segments by these location points, and the embedded tendons are constrained to the finite element mesh. They contribute stiffness to the FE model, and their strains are calculated from the displacement field of the mother shell elements, where the tendons are bonded to surrounding shell elements [22]. Each particle of a reinforcement bar is separately performed in DIANA, and the isoparametric element in the axis is divided for two particles in the numerical integration. Integration points are marked with a small triangle. In each integration point, DIANA determines an -axis tangential to the bar axis. The number of integration points is dependent on the element that the particle of the reinforcement bar is embedded in [23].

The interface element CL24I was applied for the simulation of shear key behaviors, which is a line to line connected interface element between edges of two curved shells [23] and works through the three couples of nodes on each element. The girder mesh and the internal bonded prestress tendons are shown in Figure 14.

3.2. Material Constitutive Model

In this study, the total strain-based crack model was selected to simulate the concrete crack propagation (DIANA 2008), which is defined according to the tensile and compressive concrete behaviors. According to whether the direction of crack is consistent with the direction of principal stress, the total strain-based crack model can be further divided into the fixed orientation-based crack model, the rotating orientation-based crack model, and the rotating to fixed orientation-based crack model. In this study, the rotating orientation-based crack model was selected. Meanwhile, the Rots model is chosen as the crack bandwidth specification. The Hordijk tensile softening curve, as shown Figure 15(a), was selected to simulate the tensile mechanism with the tensile strength 2.64 MPa coupled with Poisson’s reduction model. In Figure 15(a), is the tensile strength while represents the tensile fracture energy per width unit with the unit N/m or N/m in DIANA, which is MODE-I fracture energy. The compression curve adopts the fib 2010 compressive model, as shown in Figure 15(b) and the reduction model due to lateral cracking recommended in JSCE 2012 [24]. in Figure 15(b) represents the compressive strength, and the compressive strength of C50 and C40 is the same as the material test, which is 55.2 MPa and 44.3 MPa, respectively.

Structural Shell Interfaces is chosen as line to line connected interface element class. The material model of interface elements between shells adopts the Coulomb friction in order to simulate the mechanical behaviors such as tension, contact, compression, and friction between segmental shear keys of dry joints under bending. The 3D line interface between shells in DIANA is selected with both the normal and shear stiffness modulus, respectively, and stiffness and mechanic behaviors of CL24I are shown as in Figures 16(a) and 16(b), respectively. Post-tensioned force is applied as load on the numerical model of tendons according to the measured value [21]. The Newton–Raphson iteration is adopted in the nonlinear analysis, where force and displacement are combined as the convergence norm. The convergence tolerance is 0.001, and the abort criterion is 10000 times. A step size of 10 kN before 120 kN and 5 kN after that was used and the maximum number of iterations is 500 in each load step.

3.3. Numerical Simulation Results

Figures 17(a)17(f) show the numerical simulation results, where the numerical simulation results are close to the test results, indicating the presented numerical modeling is capable of accurately simulating the girder behavior. Besides, Figures 18(a)18(f) compare the increase in tendon forces, where the simulation match well with test results. Based on the validated models, parameters that are not considered in the tests are further investigated, including the thickness of top plate, the initial post-tensioned prestress force, and the area of prestress tendon and another kind of joint (i.e., the corbel joint as shown in Figure 19). Other parameters and material constitutive models are the same as for specimen 1. Table 3 summarizes the characteristics of these analysis cases; for comparison, the integral cast girder with continuous longitudinal steel reinforcements is also modeled. Analysis results are listed in Table 3, and load-deflection curves of cases 1 to 5 are shown in Figure 20.

According to Table 3, compared with PCS girders, both the ultimate flexural bearing capacity and ultimate deflection of integral cast girder are significantly larger, with the increase of 82.14% and 64.52%, respectively, mainly due to the continuity of longitudinal steel reinforcements. Besides, ultimate deflections of PCS girders with 4 segments tend to be lower than those with 5 segments. In addition, the change in initial post-tensioned load and top plate thickness do not have a significant influence on the ultimate bearing capacity, while the reduced area of prestress tendon results in both far lower ultimate bearing capacity and ultimate mid-span deflection. As expected, when larger initial post-tensioned load is adopted, the ultimate deflection becomes significantly smaller, but the ultimate bearing capacity has an insignificant change. The corbel joints, in general, show better ultimate performance than the commonly used castle-shaped joints. This might be due to the fact that as compared with the castle-shaped joint, the corbel joint has less contact surfaces and has more uniform stress distribution under bending. On the other hand, the castle-shaped joint may have more complex stress distribution due to local compression under bending, resulting in concrete crush and loss in tendon forces.

4. Conclusions

This study investigates the flexural behavior of PCS box-girders with dry joints under bending loads, which has not been studied in depth previously. Based on the presented work, conclusions are drawn as follows:(1)Specimens with only internal bonded tendons were failed under bending load due to the excessive force in tendons. Among them, larger shear span ratio had greater increase in tendon force and concrete strain during loading and, accordingly, the lowest flexural capacity. Lower concrete strength showed a significant increase in concrete strain and tendon force during loading, resulting in relatively smaller deflection at failure. With more shear keys, specimen 3 had only an insignificant influence on the girder behavior. However, for the specimen with 4 segments, a more significant increase in tendon force and small deflections at failure was observed, though the failure load was similar with specimen 1.(2)Specimen 6 adopted external tendons in addition to the internal ones; therefore, it had much larger flexural capacity and slower change in tendon force during loading; accordingly, the deflection at failure was the smallest. The failure of specimen 6 was due to the concrete crushing at top flanges, which is different from other specimens and is more similar to the over reinforcement failure.(3)Larger shear span ratio and hybrid tendons resulted in the smallest and largest cracking loads, respectively, while lower concrete strength, even number of segments, and more shear keys could result in lower cracking loads. As compared with specimen 1, there were more cracks but no crushing in specimen 5 with four segments.(4)Numerical simulation shows that the integral cast girder has larger ultimate bearing capacity and ultimate deflection compared with PCS girders. Accordingly, deflection control standard of PCS girders should be stricter than that of the integral cast girder. Besides, the changes in thickness of the top plate and initial post-tensioned force have an insignificant influence on the ultimate bearing capacity, while the area of prestress tendons significantly affects both ultimate capacity and ultimate deflection. The corbel joints, in general, show better ultimate performance than the commonly used castle-shaped joints.

Data Availability

The data used to support the findings of this study are available from the corresponding author upon request.

Conflicts of Interest

The authors declare that they have no known conflicts of interest or personal relationships that could have appeared to influence the work reported in this paper.

Acknowledgments

This research was funded by the Ministry of Science and Technology of the People’s Republic of China under Grant no. 2016YFC0701400, the National Natural Science Foundation of China under Grant no. 51908191, and China Postdoctoral Science Foundation under Grant no. 2019M660103.