Research Article

Minimizing Drying Shrinkage and Enhancing Impermeability of Foam Concrete Modified with Epoxy Resin

Table 7

Permeability coefficients of specimens b3, b4, and b5.

Test specimen no.Average depth of penetration (mm)Pressurization time (t)P (MPa)P (height of water column, mm)m (kg)Ah (m3)KP (×10−9 mm/h)

b33.33151.51530000.00020.0001333.65
b42.13151.51530000.00010.0001330.75
b58.53151.51530000.00040.00013347.81