Research Article

Multiparameter Inversion Early Warning System of Tunnel Stress-Seepage Coupling Based on IA-BP Algorithm

Table 7

Comparisons between calculated experimental values and IA-BP inversion results.

Experimental factorsCalculated test valueIA-BP algorithm inversion value
E (GPa)c (MPa)μφ (°)E (GPa)c (MPa)μφ (°)

Test 1400.40.22040.0000.4000.00020.000
Test 2400.60.252240.0000.5990.25021.999
Test 3400.80.32441.2480.8000.29424.000
Test 4450.40.252445.0000.4000.25023.999
Test 5450.60.32044.9990.6010.30020.001
Test 6450.80.22245.0010.7990.20124.000
Test 7500.40.32249.9990.4000.30020.000
Test 8500.60.22450.0000.6000.20024.000
Test 9500.80.252050.0000.7990.00024.000