Research Article

Alternative Load Path Analysis for Determining the Geometric Agreement of a Cable-Stayed Bridge with Steel Truss Girders

Table 5

The collapse performance of the bridge in the cable loss scenarios.

Failed membersNodeLoad factorMaximum displacement (mm)
AxialVertical

S91812.929580
M89013.121960
M1311012.3211150
A8-A9147.940434
A29-A305412.0531
A44-A45865.1-25406