Research Article
Fracture Modeling of the Bi-Block Ballastless Track System Resulting from Early-Aged Relative Humidity during the Construction Process
| Component | E28 (GPa) | | | ft (MPa) | D1 × 10−10 (m2.s−1) | | β | Hc (%) | am (m.d−1) |
| Sleeper | 36.0 | 0.2 | 0.3 | 1.54 | 0.25 | 0.018 | 1.3 | 98 | 0.0038 | Track slab | 32.5 | 0.2 | 0.4 | 2.39 | 0.5 | 0.022 | 1.1 | 98 | 0.0055 | Foundation | 25.5 | 0.2 | 0.6 | 2.74 | 2.02 | 0.071 | 0.8 | 98 | 0.0105 |
|
|