Research Article
Investigation on the Displacement Ductility Coefficient of Reinforced Concrete Columns Strengthened with Textile-Reinforced Concrete
Table 10
Comparison of the measured and predicted value.
| Serial number | Displacement ductility coefficient | Measured value | Predicted value | Measured/predicted value |
| 1 | 4.36 | 5.27 | 0.83 | 2 | 6.76 | 5.51 | 1.23 | 3 | 6.91 | 5.73 | 1.21 | 4 | 6.5 | 5.98 | 1.09 | 5 | 6.6 | 6.19 | 1.07 | 6 | 10.58 | 10.13 | 1.04 | 7 | 5.3 | 3.99 | 1.33 | 8 | 3.73 | 3.06 | 1.22 | 9 | 3.38 | 4.18 | 0.81 | 10 | 6.69 | 7.46 | 0.90 | 11 | 7.59 | 6.72 | 1.13 | 12 | 5.32 | 5.26 | 1.01 | 13 | 5.64 | 6.27 | 0.90 | 14 | 5.03 | 5.43 | 0.93 | 15 | 5 | 5.19 | 0.96 |
|
|