Research Article

Seismic Fragility and Life Cycle Cost Analysis of Reinforced Concrete Structures with a Hybrid Damper

Table 2

Repair cost and repair time of different damage states for the FD, XMD, and hybrid dampers for the four-storey structure.

DS-1DS-2DS-3
Repair cost (INR)Repair time (days)Repair cost (INR)Repair time (days)Repair cost (INR)Repair time (days)

FD21,600336,0007
XMD28,800343,2007
Hybrid damper10,800339,600554,00010