Research Article
Investigation on Surrounding Rock Stability Control Technology of High Stress Roadway in Steeply Dipping Coal Seam
Table 2
The distance between roof and upper coal seam of 12032 haulage roadway.
| Distance to open-off cut L (m) | 0–55 | 55–200 | 200–235 | 235–310 | 310–465 | 465–620 | 620–710 |
| Roadway length l (m) | 55.0 | 145.0 | 35.0 | 75.0 | 155.0 | 55.0 | 90.0 | Roof thickness H (m) | 1.50–1.75 | 0.85–1.50 | 1.50–2.00 | 2.00–2.50 | 2.50–3.00 | 3.00–3.50 | 3.50–3.90 | Roof classification type | II | I | II | II | III | III | IV |
|
|