Research Article

Research on Mechanical Properties and Parameter Identification of Beam-Column Joint with Gusset Plate Angle Using Experiment and Stochastic Sensitivity Analysis

Table 4

Comparison between the SJA experimental and finite element analysis results.

Moment bearing capacity (0.004 rad) (kN·m)Moment bearing capacity (0.03 rad) (kN·m)Moment bearing capacity (0.05 rad) (kN·m)
FEMTestRatioFEMTestRatioFEMTestRatio

SJA-120161.2548490.9855620.89
SJA-225260.9654501.0881621.3
SJA-32727182621.3297711.37