Research Article

Research on Mechanical Properties and Parameter Identification of Beam-Column Joint with Gusset Plate Angle Using Experiment and Stochastic Sensitivity Analysis

Table 5

Comparison between the SJB experimental and finite element analysis results.

Moment bearing capacity (0.004 rad) (kN·m)Moment bearing capacity (0.03 rad) (kN·m)Moment bearing capacity (0.05 rad) (kN·m)
FEMTestRatioFEMTestRatioFEMTestRatio

SJB-124/−2215/−141.6/1.655/−5146/−441.2/1.1675/−5771/−541.06/1.06
SJB-226/−2225/−221.04/155/−5158/−360.95/1.481/−5880/−501.01/1.16
SJB-338/−3234/−241.12/1.388/−8069/−681.28/1.18110/−9684/−791.3/1.2