Research Article
Hydrodynamic Performance and Cavitation Analysis in Bottom Outlets of Dam Using CFD Modelling
Table 3
Mesh sensitivity analysis.
| Parameters | Type of mesh | Cell size 20% smaller | Cell size 10% smaller | Main | Cell size 10% larger | Cell size 20% larger |
| Velocity (m/s) | 18.21 | 18.13 | 18.05 | 17.42 | 17.1 | Analytical velocity (m/s) | 18.9 | 18.9 | 18.9 | 18.9 | 18.9 | Error (%) | 3.65 | 4.07 | 4.49 | 7.83 | 9.52 |
|
|